Filter Change Intervals

Replace filter cartridge before getting bad air. Air quality depends mainly on cartridge condition. Therefore, it is very important to strictly follow tot the suggested intervals.

Replacement intervals are calculated taking into consideration compressor use and intake air temperature at 68 degrees F. If temperature is different, use the following table tot calculate the coefficients:

 Temperature (degrees C)

Temperature (degrees F) 

Coefficient 

 50

 122

 0,20

 40

 104

 0,34

 30

 86

 0,57

 20

 68

 1,00

 10

 50

 1,85

 5

 41

 2,60

 0

 32

 3,80

 

Model

Number of 72 ft3. or 10 L. tanks to be filled

 

volume of air

Filtre maximum

 

3000 psi / 200 b

4400 psi / 300 b

m3

hours

HL 110

150

100

300

50

 

Important

A damaged ACTIVATED CHARCOAL FILTER cartridge cannot be dumped directly into urban dumpsters.

Service the filter only if the chamber is depressurized and the compressor is off. Make sure the O-rings are OK. Replace if necessary. Leave the filter cartridge inside of the filter chamber while the compressor is not in use.